Appendix AXD Tools Test Reference 35
Power Supply Tests
Processor Tests
Sensor Tests
USB Tests
Connect USB devices before running USB tests.
Extended Memory Test P02F 5 seconds Tests memory using pattern 2. This
fails if an error occurs.
Extended Memory Test P03F 5 seconds Tests memory using pattern 3. This
fails if an error occurs.
Extended Memory Test P04F 5 seconds Tests memory using pattern 4. This
fails if an error occurs.
Extended Memory Test P05F 5 seconds Tests memory using pattern 5. This
fails if an error occurs.
Extended Memory Test P06F 5 seconds Tests memory using pattern 6. This
fails if an error occurs.
Extended Memory Test P07F 5 seconds Tests memory using pattern 7. This
fails if an error occurs.
Test Estimated completion time Description
Test Estimated completion time Description
Good Bit 1 second Checks if the power supply’s good bit
is set. If it’s not set, this could indicate
that the power supply isn’t seated
well, is bad, or that there’s no AC
connected.
Quick 5 seconds This is available only if you have more
than one power supply. This turns off
the redundant power supplies so that
only one power supply is used.
Test Estimated completion time Description
L1 Cache Test 1 second Verifies that the L1 cache is good on
all processor cores
Test Estimated completion time Description
Sensor Reads 1 second Verifies that the sensor reads are
within the preset sensor limits
Test Estimated completion time Description
Presence 1 second Verifies that a USB device is connected
Commentaires sur ces manuels