Xserve (Late 2006) Processor Heat Sink Replacement Instructions 10
Replacing the Airow Duct
Lower the airow duct into position on the logic board.
Note: When installing the airow duct, be sure to route both the front panel board cable and
the backplane-to-logic board I/O cable inside the channel under the left side of the duct.
Ensure the airow duct ts ush all over, and does not protrude above the enclosure.
Note: Be careful when working with any black foam pieces that are part of the airow duct
or the logic board.
Tighten the ve Phillips screws that fasten the airow duct to the fan array, in the order
shown, to prevent the duct from warping. Do not overtighten the screws.