8 Chapter 1
Installing Your Xserve G5 PCI Hardware RAID Card
2
Move to the front of the server and open it to its full length. Remove the server from
the rack (leaving the cover in place) and put the server on a sturdy flat surface.
See “Opening and Closing the Server on page 72 of the
Xserve G5 User's Guide
for
details.
3
Loosen the thumbscrew on the PCI slot covers on the back panel and swivel open the
small metal piece that holds the thumbscrew.
4
Locate the PCI slots at the back left side of the server.
You must install the PCI Hardware RAID Card in the bottom slot. If you have an existing
card in that slot, move it to the upper slot to free up the lower slot for the RAID card.
Loosen the thumbscrew and
swing the small metal plate
to its open position.
PCI card slots (2)
Slot covers